Eaton Rigid Tube Assembly Repair

Record of revisions:
2/14/25: Add Rynglok Installation video to References
Team members required: Two
Description:
Rigid Tube Assembly Repair using Rynglok Axial Swage Tube Fitting System
References:
Eaton bulletin TF100-138 Rynglok Fitting System Installation Sequence
Eaton bulletin TF100-1F- Hydraulic Tube Fitting System
Eaton bulletin TF100-75 Rynglok Fitting System AS-Standards Cross Reference
AS5958 Fittings, Axial Swaged Tube with Flareless Separable, Fitting System 5080 psi Specification
US Navy NAVAIR 01-1A-20 Hydraulic hose and tube manual
US Airforce TO 42E1-1-1 Hydraulic hose and tube manual
Rynglok Installation - Aerospace - Eaton videos
Tools and equipment list:
See Eaton Bulletin TF100-138 that lists the following tools needed by assembly step.
• Step 1 RTSGO-01-08 marking gauge.
• Step 3 Rynglok -08 Assembly Tool, hose assembly (P/N RTST8-02-08), Quick Disconnect Coupling and hand pump.
• Step 5 Fitting swage inspection gauge RTSGO-51-08.
Instructions:
See Eaton Bulletin TF100-138 for assembly steps.
Scoring:
Scores will be calculated according to the AMC score sheet. Penalties will be assessed for following:
1. Step 1 - Not selecting the correct RTSGO-01-08 Tool from the tool kit.
2. Step 1 - Not marking tube correctly using RTSGO-01-08 Tool and marking pen.
3. Step 2 – Not inserting the fitting to the correct depth on the tube per the position mark.
4. Step 3 – Not selecting the correct size tool from the tool kit.
5. Step 5 – Not swaging the fitting correctly and not passing the visual inspection using gauge RTSGO-51-08.
For More Information: