Eaton Rigid Tube Assembly Repair


Tuesday, April 8, 2025
to Wednesday, April 9, 2025

Record of revisions: 

2/14/25: Add Rynglok Installation video to References

Team members required: Two

Description:

Rigid Tube Assembly Repair using Rynglok Axial Swage Tube Fitting System 

References:

Eaton bulletin TF100-138 Rynglok Fitting System Installation Sequence 

Eaton bulletin TF100-1F- Hydraulic Tube Fitting System

Eaton bulletin TF100-75 Rynglok Fitting System AS-Standards Cross Reference 

AS5958 Fittings, Axial Swaged Tube with Flareless Separable, Fitting System 5080 psi Specification 

US Navy NAVAIR 01-1A-20 Hydraulic hose and tube manual 

US Airforce TO 42E1-1-1 Hydraulic hose and tube manual 

Rynglok Installation - Aerospace - Eaton videos

Tools and equipment list:

See Eaton Bulletin TF100-138 that lists the following tools needed by assembly step. 

• Step 1 RTSGO-01-08 marking gauge. 

• Step 3 Rynglok -08 Assembly Tool, hose assembly (P/N RTST8-02-08), Quick Disconnect Coupling and hand pump. 

• Step 5 Fitting swage inspection gauge RTSGO-51-08. 

Instructions:

See Eaton Bulletin TF100-138 for assembly steps. 

Scoring:

Scores will be calculated according to the AMC score sheet. Penalties will be assessed for following: 

1. Step 1 - Not selecting the correct RTSGO-01-08 Tool from the tool kit. 

2. Step 1 - Not marking tube correctly using RTSGO-01-08 Tool and marking pen. 

3. Step 2 – Not inserting the fitting to the correct depth on the tube per the position mark. 

4. Step 3 – Not selecting the correct size tool from the tool kit. 

5. Step 5 – Not swaging the fitting correctly and not passing the visual inspection using gauge RTSGO-51-08. 

For More Information: